RO Pure Water Treatment is the most precise membrane liquid separation technology. The operating pressure is applied on the side of the inlet water and the concentrated solution to overcome the natural osmotic pressure.
When the operating pressure higher than the natural osmotic pressure is dropped on the side of the concentrated solution water molecules naturally permeate the flow The direction will be reversed, and the water molecules in the influent concentrated solution pass through the reverse osmosis membrane to become the purified water om the dilute solution side Reverse osmosis suitable equipment can block all soluble salts and organic substances with a molecular weight greater than 100. but allow water molecules to pass through, The salt rejection rate of reverse osmosis composite membranes is generally greater than 98%.
Úprava čistej vody RO
Most of our projects use DOW Filmtec, Toray, Vontron, Hydranautics, LG brands. They are well-known brands in the water treatment industry.
The reverse osmosis membrane is the core element to realize reverse osmosis, and it is an artificial semipermeable membrane with certain characteristics made by simulating biological semipermeable membrane. Generally made of polymer materials. Such as cellulose acetate film, aromatic polyhydrazide film, aromatic polyamide film. The diameter of the surface pores is generally between 0.5 and 10 nm, and the permeability is related to the chemical structure of the membrane itself. Some polymer materials have good repellency to salt, but the permeation speed of water is not good. The chemical structure of some polymer materials has more hydrophilic groups, so the permeation speed of water is relatively fast. Therefore, a satisfactory reverse osmosis membrane should have an appropriate amount of permeation or salt rejection.
Additionally, commercial RO water treatment systems can incorporate chemicals such as anti-scaling (scaling inhibitors), anti-fouling, pH adjustment, sterilization and disinfection chemicals in the pre- or post-treatment. We keep a close eye on the water treatment industry and add new water technologies to our reverse osmosis water plants.
When checking the customer's water quality analysis report, sometimes due to scaling and scaling problems, we can use the CIP (cleaning-in-place) system to clean the membrane in the membrane shell to make the membrane longer life. It is a new type of water treatment technology most used in the water treatment industry.
Elektrická energia komerčných systémov úpravy vody RO
Pre komerčné zariadenie na čistenie vody potrebuje 220-380V / 50Hz / 60Hz. Pre väčšiu kapacitu najmä pre priemyselný systém reverznej osmózy, kvôli vysokotlakovému čerpadlu, potrebuje 380V 50/60Hz. Pokiaľ ide o konštrukciu vášho komerčného zariadenia na filtráciu vody s reverznou osmózou, skontrolujeme vaše elektrické napájanie a rozhodneme o pevnom napájaní pre vás. Máme tiež niektoré metódy úspory energie na zníženie nákladov na elektrickú energiu, nové technológie úpravy vody Chunke vám pomôžu znížiť najväčšie náklady na prevádzku systému.
Pred zakúpením komerčného systému čistenia vody by ste mali vedieť:
1. Kapacita výroby čistej vody (l / deň, l / hodina, GPD).
2. Správa o analýze TDS napájacej vody a surovej vody (predchádzanie problému so znečistením a tvorbou vodného kameňa)
3. Železo a mangán sa musia odstrániť predtým, ako surová voda vstúpi do membrány filtrácie vody s reverznou osmózou
4. TSS (celková nerozpustná tuhá látka) sa musí pred komerčným systémom čistenia vody odstrániť.
5. SDI (index hustoty bahna) musí byť menší ako 3
6. Musíte sa uistiť, že váš zdroj vody nemá olej a mastnotu
7. Pred komerčným systémom úpravy vody sa musí odstrániť chlór
8. Dostupné elektrické napätie a fáza
9. Usporiadanie miesta pre komerčný systém RO reverznej osmózyPrevádzková špecifikácia pre komerčné RO systémy úpravy vody
TDS napájacej vody: 0 - 1000ppm
|
Tvrdosť nad 18ppm Vyžaduje dávkovanie antiscalantu
|
Zákal musí byť
Odstránený
|
Max. teplota napájacej vody: 42°C
|
Pracujte s vyššími výsledkami TDS nižšími
Zotavenie
|
H2S musí byť
Odstránený
|
Tolerancia pH: 3 – 11
|
Max. obsah železa: 0.05ppm
|
|
Tlak napájacej vody: 1,5 až 6 bar
|
Max. tolerancia oxidu kremičitého: 60ppm
|
|
Contact us to learn more about our industrial reverse osmosis systems and commercial RO water plants. Our sales team and technical team will be happy to share new water treatment technologies for your project.